1 | RM110V12KC3 | Dual output voltage Power Supply System

  • 400Vac Input (without neutral) / 50Hz / PFC > 0.99
  • Isolation power input transformer 12kVA or 18kVA
  • 2 output at 110Vdc (3xFR4K-80A or 3xFR6K-120A)
  • 2 output at 48Vdc (3xConverters DC/DC FC 45A)
  • 12kW (FR4K) or 18kW (FR6K) Output Power
  • Modular design (N+1) for flexible configuration
  • Rotating interior door for access to all components
  • Hot plugging Switching rectifier (FR4K or FR6K)
  • Hot plugging DC/DC Converters (FC)
  • Hot plugging diode reduction module (MDR)
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of MSC failure or extraction, the 110Vdc and 48Vdc remain at the predefined values
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

2 | SAR2xRM110V36K | Dual independent DC Power Supply System

  • 2xRM…V36K Rectifiers + 1 (AI) Interconnector Cabinet
  • Input: 400Vac / 50Hz / PFC > 0.99
  • 2 isolated busbars of 250Vdc, 110Vdc or 48Vdc
  • Output Power up to 72 kW (36 kW + 36 kW)
  • Modular design (N+1) for flexible configuration
  • Switching Rectifier Modules type FR6K250V/120V/48V
  • 12 (6+6) Hot plugging Switching Rectifier Modules
  • 2 Hot plugging ground fault detection unit (DPT) Busbar1 and 2
  • 2 independent DC maximum voltage sensors (SMT)
  • 2 10″ touch color screen HMI webserver mirror
  • 2 Hot plugging supervision and control module (MSC)
  • Resident Webserver software (HTML5) on each MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of MSC failure or extraction, all output voltages remain at predefined values
  • Interconnector Cabinet (AI) on each Bars: Battery and Rectifiers protection, automatic and manual closing Interbar, diodes reducers, meter devices, DPT and DC distribution
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

3 | RM110V36K3SDO | Three output voltage Power Supply System

  • Input: 400Vac / 50Hz / PFC > 0.99
  • 110Vdc Output (6xFR4K-150A or 3xFR6K-240A)
  • 48Vdc Output (3xConverters DC/DC SD 48Vdc/66A)
  • 230Vac Output (4xInverters Bravo25 230Vac/40A)
  • Modular design (N+1) for flexible configuration
  • Hot plugging Switching rectifier FR120V/40A
  • Hot plugging SD DC/DC Converters
  • Hot plugging Bravo 25 DC/AC inverters
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of MSC failure or extraction, the 110Vdc, 48Vdc, 230Vac remain at the predefined values
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

4 | RM110V12KC4O | System Four output voltage Power Supply System

  • Input: 400Vac / 50Hz / PFC > 0.99
  • 12kVA or 18kVA Isolation power input transformer
  • 110Vdc Output (3xFR4K-80A or 3xFR6K-120A)
  • 48Vdc Output (3xSD Converters DC/DC-48/22A)
  • 12Vdc Output (1xFC Converter DC/DC-12/30A)
  • 230Vac Output (4xBravo25 230Vac/40A)
  • Modular design (N+1) for flexible configuration
  • Rotating interior door for access to all components
  • Hot plugging FR Switching rectifier
  • Hot plugging SD DC/DC Converters
  • Hot plugging Bravo DC/AC inverters
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of MSC failure or extraction, all output voltages remain at predefined values
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

5 | RM110V12KC2Q | Two Voltage DC Output System with Distribution Board Included

  • Input: 400Vac (without neutral) / 50Hz / PFC > 0.99
  • 12kVA or 18kVA Isolation power input transformer
  • 110Vdc Output (3xFR4K-80A or 3xFR6K-120A)
  • 48Vdc Output (2xFC Converters DC/DC-30A)
  • Modular design (N+1) for flexible configuration
  • 110Vdc Distribution Panel with 10 protected outputs
  • 48Vdc Distribution Panel with 4 protected outputs
  • Hot plugging FR Switching rectifier
  • Hot plugging SD Converters DC/DC
  • Hot plugging diode reduction module (MDR)
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of MSC failure or extraction, the 110Vdc and 48Vdc remain at the predefined values
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

6 | SAR2xRM+2FC+2QDCC | Example of a Special Project in service since 2012 at the Belo Jardim Power Plant on Terceira Island (Azores)

  • 2 Rectifiers Cabinets of 110Vdc
  • 2 Converters DC/DC Cabinets of 24Vdc
  • 1 Distribution Cabinet of 110Vdc
  • 1 Distribution Cabinet of 24Vdc
  • Input: 400Vac/230Vac-50Hz/CFP > 0.99
  • Output at 110Vdc / 480A internal bus (12xFR6K-120Vdc/40A)
  • Output at 24Vdc / 540A internal bus (FC type DC/DC Converters)
FOR MAXIMUM CAPACITY IN OTHER SPECIAL PROJECTS:
  • 6 Rectifiers Cabinets of 110Vdc
  • 4 Converters DC/DC Cabinets of 48Vdc or 24Vdc
  • 2 Distribution Cabinet of 110Vdc
  • 2 Distribution Cabinet of 48Vdc or 24Vdc
  • Input: 400Vac/230Vac-50Hz/CFP > 0.99
  • Output at 110Vdc / 1500A internal bus (36xFR6K-120Vdc/40A)
  • Output at 48Vdc or 24Vdc up to 2000A internal bus (SD type DC/DC Converters)
  • Hot Plugging FR Switching rectifier and DC/DC converters (FC and SD)
  • Hot Plugging ground fault detection unit (DPT)
  • Independent 110Vdc Maximum Voltage Sensor (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot Plugging (MSC) Supervision and Control Module
  • MSC Software Webserver resident (HTML5)
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / other
  • Emergency mode, in case of failure or extraction of the MSC, the Output voltages remain at the predefined values
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity