1 | RM110V12KC2O | System of two DC output voltages and one AC output voltage

  • Input: 400Vac / 50Hz / PFC > 0.99
  • Isolation power input transformer 12kVA or 18kVA
  • 2 Outputs at 110Vdc (3xFR4K-80A or 3x6K-120A)
  • 2 Outputs at 48Vdc (2xFC DC/DC-30A Converters)
  • 2 Output at 230Vac (4xBravo 25 230Vac/40A Inverters)
  • Modular design (N+1) for flexible configuration
  • Rotating interior door for access to all components
  • Hot plugging Switching rectifier (FR)
  • Hot plugging DC/DC Converters (FC)
  • Hot plugging DC/AC inverters (Bravo25)
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of MSC failure or extraction, the 110Vdc, 48Vdc, 230Vac remain at the predefined values
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

2 | RM110V12KO | System of one DC output voltage and one AC output voltage

  • Input: 400Vac / 50Hz / PFC > 0.99
  • Isolation power input transformer 12kVA or 18kVA
  • 2 Outputs at 110Vdc (3xFR4K-80A or 3x6K-120A)
  • 2 Output at 230Vac (4xBravo 25 230Vac/40A Inverters)
  • Modular design (N+1) for flexible configuration
  • Rotating interior door for access to all components
  • Hot plugging Switching rectifier (FR)
  • Hot plugging DC/AC inverters (Bravo25)
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of MSC failure or extraction, the 110Vdc and 230Vac remain at the predefined values
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

3 | RM110V12KO+BAT | System of one DC output voltage, one AC output voltage plus 110V Battery in the same Cabinet

  • Input: 400Vac / 50Hz / PFC > 0.99
  • Isolation power input transformer 12kVA
  • 110Vdc output (3xFR4K-80A in total)
  • 230Vac output (4xBravo 25 230Vac/40A in total)
  • Modular design (N+1) for flexible configuration
  • Hot plugging Switching rectifier (FR)
  • Hot plugging DC/AC inverters (Bravo25)
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of failure or extraction of the MSC, the Voltage of 110Vdc and 230Vac remains at the predefined values
  • 3 removable shelves with liquid drainage for the basin retention with capacity to receive 90 Ni-Cd battery elements up to 100Ah capacity (other solutions available)
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

4 | RM110V12K3SD+BAT | Two DC output voltage system plus 110V Battery in the same Cabinet

  • Input: 400Vac / 50Hz / PFC > 0.99
  • Isolation power input transformer 12kVA
  • 110Vdc output (3xFR4K-80A in total)
  • 48Vdc output (4xDC/DC SD Converters 66A in total)
  • Modular design (N+1) for flexible configuration
  • Hot plugging Switching rectifier (FR)
  • Hot plugging DC/DC Converters (SD)
  • Hot plugging ground fault detection unit (DPT)
  • Independent maximum voltage sensor 110Vdc (SMT)
  • 10″ touch color screen HMI webserver mirror
  • Hot plugging supervision and control module (MSC)
  • WebServer Software (HTML5) residing inside MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / others
  • Emergency mode, in case of failure or extraction of the MSC, the Voltage of 110Vdc and 48Vcc remains at the predefined values
  • 3 removable shelves with liquid drainage for the basin retention with capacity to receive 90 NiCd battery elements up to 100Ah capacity (other solutions available)
  • Battery Status and Charge Management
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

5 | SOC110-24-48-230 | Two DC/DC Converter System and one DC/AC Inverters System

  • Two independent inputs, both 110VDC
  • Common output at 48Vdc (3 DC/DC SD Converters – 66A)
  • Common output at 24Vdc (3 DC/DC SD Converters – 120A)
  • Common output at 230Vac (4 Bravo 25 – 10kW Inverters)
  • Modular design (N+1) for flexible configuration
  • Hot plugging DC/DC Converters (SD)
  • Hot plugging DC/AC Inverters (Bravo 25)
  • Automatic bypass without micro-cuts / Manual bypass
  • Interconnection with the RM range Power Energy System via an easy-fitting Harting-type connector and supplied by Fisocrom
  • Information sent to the MSCs of RM range power supply systems includes Information on the output voltages and currents of the DC/DC Converters and DC/AC Inverters
  • In the MSC of both power supply systems (RM) it is possible to access the resident Webserver Software (HTML5) and use TCP/IP Communications, IEC61850, IEC60870-5-104, as well as use a 10” touch screen console (HMI) to view the menus with the information from this SOC system
  • Warranty of 2 to 5 Years
  • EU Declaration of Conformity

6 | SAR+SOC | Integrated System for High Voltage Substations

GENERAL FEATURES SAR2XRM110V36K DUAL DC POWER SYSTEM
  • 2 RM Rectifiers… V36K + 1 Interconnecting Cabinet (AI)
  • Input: 400Vac / 50Hz / CFP > 0.99
  • 2 Isolated 250Vdc, 110Vdc or 48Vdc busbars
  • Output Power up to 72kW (36 kW + 36 kW)
  • Flexible modular configuration (N+1)
  • Switching Rectifier Modules type FR6K250V/120V/48V
  • 12 (6+6) Hot Plugging Switching Rectifier Modules
  • 2 Hot Plugging Ground Fault Detection (DPT) Units
  • 2 Independent Maximum DC Voltage (SMT) Sensors
  • 2 x 10″ touchscreen consoles (HMI) identical to Webserver
  • 2 Hot Plugging Supervision and Control Modules (MSC)
  • Resident Webserver Software (HTML5) on each MSC
  • Communications TCP/IP / IEC61850 / IEC60870-5-104 / other
  • Emergency mode, in the event of failure or extraction of the MSC, all output voltages remain at the predefined values
  • Busbar interconnecting cabinet: protection and cut-off of batteries and rectifiers, automatic and manual closing of Interbar, reducing diodes, measuring devices, DPT and DC distribution
  • Flexibility for various types of batteries
  • Battery Status and Charge Management
GENERAL FEATURES – SOC110-24-48-230 – DC/DC CONVERTER SYSTEM AND DC/AC INVERTERS
  • Two independent inputs, both 110V DC
  • Common output at 48Vdc (3+3 DC/DC SD Converters – 130A)
  • Common output at 230Vac (4+4 Bravo Inverters 25 – 20KW)
  • Flexible modular configuration (N+1)
  • Hot Plugging DC/DC (SD) converters
  • Hot Plugging DC/AC inverters (Bravo 25)
  • Automatic bypass without micro-cuts / Manual bypass
  • Interconnection with the RM range Power Energy System via an easy-fitting Harting-type connector and supplied by Fisocrom
  • Information sent to the MSC’s of the RM range power supply systems includes: Information on the output voltages and currents of the DC/DC Converters and DC/AC Inverters
  • On the MSC of both power systems, it is possible to access the resident Webserver Software (HTML5) and use TCP/IP Communications, IEC61850, IEC60870-5-104, as well as use a 10″ touch screen console (HMI) to view the menus with the information of this SOC system
  • RAL7032/35 or RAL2005
  • 2 to 5 Year Warranty
  • EU Declaration of Conformity